Delta Electronics RTU-EN01 Instrukcja Użytkownika Strona 61

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 62
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 60
Ethernet Communication Module DVPEN01-SL
3.
Use DCISoft for DVPEN01-SL to set start addresses and numbers. (RX: M2000~M2009; RY: M3000~M3009;
RCR (Reading): D2000~D2009; RCR (Writing): D3000~D3009)
4. Edit a ladder diagram, and download it to DVPEN01-SL. The program edited is like the one shown below.
Explanations:
1. Enabling mapping: CR15=1
2. Disabling mapping: CR15=0
3. After CR#15 is enabled, M2000~M2009 and D2000~D2009 will be used to read data, and present values will be
read before M3000~M3009 and D3000~D3009 are used to write data.
4. During the execution of mapping, other devices can not be used to modify the values in mapping registers.
DVP-PLC Operation Manual
59
Przeglądanie stron 60