Delta Electronics RTU-EN01 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Zdalne sterowanie Delta Electronics RTU-EN01. Ethernet Communication Module DVPEN01-SL Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - DVPEN01-SL

DVPEN01-SL Ethernet Communication Module Operation Manual DVP-0204320-03

Strona 2

Ethernet Communication Module DVPEN01-SL 4.2 Explanations on CR CR#0: Model code Explanations: 1. Model code of DVPEN01-SL=H’4050. 2. You can read

Strona 3 - Warning

Ethernet Communication Module DVPEN01-SL  Data Exchange CR#13: Data exchange trigger Explanations: CR#13 Execution 0 The data in data exchange ar

Strona 4 - DVP-PLC Operation Manual

Ethernet Communication Module DVPEN01-SL CR#27: Function code for a data exchange mode Explanations: 0: Using the function code “0x17” for the reading

Strona 5 - 1 Introduction

Ethernet Communication Module DVPEN01-SL CR#85: Written-in address for data exchange Explanations: The number of transmission registers (K1~K100) in

Strona 6 - 2.4 RJ-45 PIN Definition

Ethernet Communication Module DVPEN01-SL CR#94: Enabling the setting of an IP address Explanations: If the value in CR#94 is 1, the setting of an IP a

Strona 7 - 3 Installation & Wiring

Ethernet Communication Module DVPEN01-SL CR value Data exchange status 0 The data have not been received. 1 The data exchange is in progress. 2 Th

Strona 8 - 4 Control Register (CR)

Ethernet Communication Module DVPEN01-SL CR#16: Connection status of the RTU mapping slave Explanations: b3~b0 display the connection status of RTU sl

Strona 9

Ethernet Communication Module DVPEN01-SL 2. Select Ethernet as the transmission type.  Broadcast search 1. Click Search in DCISoft to search for a

Strona 10 - 4.2 Explanations on CR

Ethernet Communication Module DVPEN01-SL 2. Click a model on the left hand side, and you will see the device list of the model selected on the right h

Strona 11

Ethernet Communication Module DVPEN01-SL  Designating a model to search 1. Right click Ethernet on the left hand side window and click Configure t

Strona 13

Ethernet Communication Module DVPEN01-SL 3. List of the current DVPEN01-SL modules  Searching by an IP address 1. Select Ethernet in the Communica

Strona 14

Ethernet Communication Module DVPEN01-SL 2. Click IP Search to start searching for the designated IP address. 3. The DVPEN01-SL module found will b

Strona 15

Ethernet Communication Module DVPEN01-SL  Opening the DVPEN01-SL setup page by RS-232 1. Select RS232 as the transmission type in the Communication

Strona 16 - 5 Setting the Software

Ethernet Communication Module DVPEN01-SL 5.2 Basic Settings The basic settings include parameters as module name, language, enabling MODBUS TCP and t

Strona 17

Ethernet Communication Module DVPEN01-SL as an offset from Greenwich Mean Time (see also UTC). Standard time zones can be defined by geometrically sub

Strona 18

Ethernet Communication Module DVPEN01-SL 3. Click on Internet Protocol (TCP/IP). 4. Enter 192.168.0.1 into the IP address box. Click on OK to compl

Strona 19

Ethernet Communication Module DVPEN01-SL 1. IP Configuration There are two types of IP address, static IP addresses and DHCP. Static IP address: Pres

Strona 20

Ethernet Communication Module DVPEN01-SL 5.4 Setting E-mails E-mail is the abbreviation of electronic mail, which transmits mails through the network

Strona 21

Ethernet Communication Module DVPEN01-SL allowed). 4. Selecting recipients: After you have set all the parameters for the E-mail, you will need to sel

Strona 22

Ethernet Communication Module DVPEN01-SL 5.6 Data Exchange DVPEN01-SL is able to designate a data exchange area for PLC MPUs to exchange and synchron

Strona 23 - 5.2 Basic Settings

Ethernet Communication Module DVPEN01-SL Warning  Please read this instruction carefully before use and follow this instruction to operate the devic

Strona 24 - 5.3 Network Settings

Ethernet Communication Module DVPEN01-SL 5.7 MELSEC Protocol DVPEN01-SL can communicate with Mitsubishi devices by means of the MELSEC protocol. It c

Strona 25

Ethernet Communication Module DVPEN01-SL  Settoing the MELSEC protocol data exchange 1. Enable MELSEC Protocol Users can disable/enable the MELSEC

Strona 26

Ethernet Communication Module DVPEN01-SL 5. Please refer to section 6.15 for more information. 5.8 RTU Use the RTU function to conduct mapping betwee

Strona 27 - 5.4 Setting E-mails

Ethernet Communication Module DVPEN01-SL 5.9 IP Filter An IP filter is used for restricting the connection of the network in case some uncertain IP a

Strona 28 - 5.5 SNMP

Ethernet Communication Module DVPEN01-SL 5.10 Static ARP Table ARP (Address Resolution Protocol) is used for obtaining the MAC address corresponding

Strona 29 - 5.6 Data Exchange

Ethernet Communication Module DVPEN01-SL 5.11 Setting a Password To prevent the set values in DVPEN01-SL from being modified, you can set a password

Strona 30 - 5.7 MELSEC Protocol

Ethernet Communication Module DVPEN01-SL 5.12 Returning to Default Settings If you need to clear all the settings after many modifications on the set

Strona 31

Ethernet Communication Module DVPEN01-SL 2. Start WPLSoft, and click Ethernet in the Communication Setting Section. 3. Click Auto-Search Ethernet

Strona 32 - 5.8 RTU

Ethernet Communication Module DVPEN01-SL 5. After DELTA DVPEN01-SL in the Ethernet section is double-clicked, DCISoft will be started. Please refer to

Strona 33 - 5.9 IP Filter

Ethernet Communication Module DVPEN01-SL 6.2 Connecting the PC with DVPEN01-SL through LAN Application Setting the network parameters of DVPEN01-SL

Strona 34 - 5.10 Static ARP Table

Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 2 5.9 IP Filter ...

Strona 35 - 5.11 Setting a Password

Ethernet Communication Module DVPEN01-SL 4. All the devices connected to the network are shown in the Ethernet section. After DELTA DVPEN01-SL is clic

Strona 36 - 6 Application Examples

Ethernet Communication Module DVPEN01-SL 6. After the setting of an IP address is complete, and step 2~step 4 are repeated, the IP address can be used

Strona 37

Ethernet Communication Module DVPEN01-SL 3. Select the Modify checkbox, and enter “aabb” in the Password box and the Confirm Password box. Click on OK

Strona 38

Ethernet Communication Module DVPEN01-SL 5. Enter the password to temporarily unlock the protection and modify the parameters. If you close the setup

Strona 39

Ethernet Communication Module DVPEN01-SL 7. After the password is cleared, you can modify the parameters. 6.4 When the Password is Lost (Returning t

Strona 40

Ethernet Communication Module DVPEN01-SL 2. After the Factory Setting box is selected, a confirmation window will appear. Click on Yes to return to de

Strona 41

Ethernet Communication Module DVPEN01-SL 3. Select the Enable IP Filter checkbox. Enter “192.168.0.4” in the No. 1 IP Address box and “255.255.255.255

Strona 42

Ethernet Communication Module DVPEN01-SL 6.6 Setting a Static ARP Table Application Setting a static ARP table Network environment (1) MAC address

Strona 43

Ethernet Communication Module DVPEN01-SL 4. Enter “192.168.1.1” in No.2 IP Address box, and its MAC address is “00:18:23:10:00:04”. Click on OK to com

Strona 44

Ethernet Communication Module DVPEN01-SL 6.7 Application of E-mails Application Sending an E-mail to notify the administrator when the current statu

Strona 45

Ethernet Communication Module DVPEN01-SL 1 Introduction Thank you for choosing DVPEN01-SL module. To correctly install and operate DVPEN01-SL, please

Strona 46

Ethernet Communication Module DVPEN01-SL 4. After all the settings in DVPEN01-SL are completed, compile the ladder diagram in the MPU and download it

Strona 47

Ethernet Communication Module DVPEN01-SL 3. Select the Enable Data Exchange checkbox. Select Program Control in the Enable Confition drop-down list bo

Strona 48

Ethernet Communication Module DVPEN01-SL detect by the previous setting that No. 1 IP address is “192.168.0.4".  Write the data in RTC into CR#

Strona 49 - 6.7 Application of E-mails

Ethernet Communication Module DVPEN01-SL 3. Select the Enable Data Exchange checkbox. Select Always Enable in the Enable Condition drop-down list box.

Strona 50

Ethernet Communication Module DVPEN01-SL 6.10 Application of Data Exchange (3) Firmware version 2.0 and above support this function. Application Enab

Strona 51

Ethernet Communication Module DVPEN01-SL 4. After all the settings in PLC_A are completed, you have to write a ladder diagram for the MPU and download

Strona 52 - K7D0K49K100FROM

Ethernet Communication Module DVPEN01-SL Explanations:  The data exchange will be executed every one second.  Write “0” into CR#28, and PLC_B wil

Strona 53

Ethernet Communication Module DVPEN01-SL ENDSET M2M1RSTK100K1M2K14 D14RST M2RST M2= D14 K2= D14 K3FROMK100 K1TOPK100TOP K1 K1K0K14K13K100TOPK1K86

Strona 54

Ethernet Communication Module DVPEN01-SL 6.13 Application of MODBUS TCP Master Application Compiling MODBUS instruction by PLC_B, making Y0 of PLC_A

Strona 55

Ethernet Communication Module DVPEN01-SL K100K1TOPK100TOP K1 K1K0K100K1TOPK100TOPK1H0K6K125K119K116K115SET M2M1RSTMOV K0 D0= D0 K2INC D0ENDK100 K1M2

Strona 56

Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 4 Item Specification Weight (g) 92 (g) 2 Product Profile & Outline 2.1 Dimen

Strona 57

Ethernet Communication Module DVPEN01-SL 6.14 RTU Mapping Application Using RTU mapping to read/write the remote digital I/O and analog I/O registers

Strona 58

Ethernet Communication Module DVPEN01-SL 3. Use DCISoft for DVPEN01-SL to set start addresses and numbers. (RX: M2000~M2009; RY: M3000~M3009; RCR (Rea

Strona 59

Ethernet Communication Module DVPEN01-SL 6.15 Application of the MELSEC Protocol Application Using Always Enable in the Enable Condition drop-down l

Strona 60

Ethernet Communication Module DVPEN01-SL 3 Installation & Wiring This section gives instructions on how to connect DVPEN01-SL with PLC MPU and ho

Strona 61

Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 6 3.2 Connecting DVPEN01-SL to the Network: Connect DVPEN01-SL to the Ethernet Hub

Strona 62

Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 7CR# HW LW Attribute Content Explanation #19 #18 R Error status of slaves in dat

Komentarze do niniejszej Instrukcji

Brak uwag