Chapt er 5 Ex am ples of Pr o gramming
5-1 3
5.4 PWMSprayer Valve Control Program
25%
50%
100%
X2 X3 X4
X0
X1
START
STOP
1. Control purpose
In order to reduce the energy lost during the gradual shut-down/start-up process, we apply
the switching method which immediately turns on and turns off the current valve. The
switching method is somewhat like cutting off a current, and is therefore called a clipper.
However, in the practical application we put a transistor between the power and the motor to
perfom the function of a clipper. A pulse signal will be applied to the base of the transistor so
as to generate a pulse current between the base and the emitter. The input voltage of motor
is in proportion to the t
on
/t
off
value. Therefore, the motor voltage could be adjusted by
modulating the t
on
/t
off
value. There are various methods for modulating this value, and the
most common one is to adjust the time (t
on
) for which the valve is ON rather than adjusting
the number of times the valve is ON during a a particular length of time. The method is
called PWM (Pulse-width modulation).
Users can control the the degree to which the sprayer vale is opened by adjusting the t
on
/t
off
value of PWM (24 V). The opening degrees which can be selected are 25%, 50%, and
100%.
2. Devices
Device Function
X0 X0 is ON when the START button is pressed.
X1 X1 is ON when the STOP button is pressed.
X2 X2 is ON when the 25% button is pressed.
X3 X3 is ON when the 50% button is pressed.
X4 X4 is ON when the 100% button is pressed.
Y0 Controlling the degree to which the the valve is opened
D0
The degree to which the the valve is opened
is stored in
D0.