Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
Revision January, 2008, Doc. Name: 2007PDD23000007 1-95
MKS MC700/720 Motion Controller Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1.
Controller Station number: 11
(NOTE 1)
.
Control area/status area: None / None.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type Format
Word No. Bit No.
Data Length
General Parameters GPn n: 0 ~ 31 N/A Double Word
Parameter Block for Slave 1 PB1_n n: 0 ~ 31 N/A Double Word
Parameter Block for Slave 2 PB2_n n: 0 ~ 31 N/A Double Word
Parameter Block for Slave 3 PB3_n n: 0 ~ 31 N/A Double Word
Parameter Block for Slave 4 PB4_n n: 0 ~ 31 N/A Double Word
Process Data PRODn n: 0 ~ 31 N/A Double Word
Communication Settings CSETn n: 0 ~ 31 N/A Double Word
Setup Settings STUPn n: 0 ~ 31 N/A Double Word
Status of Commands and
Outputs
S_COn n: 0 ~ 4 N/A Double Word
Contacts
Read/Write Range
Contact type Format
Word No. Bit No.
Commands CMDb N/A b: 0 ~ 31
Outputs OUTb N/A b: 0 ~ 31
Status of Commands and
Outputs
S_COn.b n: 0 ~ 4 b: 0 ~ 31