Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-100 Revision January, 2008, Doc. Name: 2007PDD23000007
Contacts
Read/Write Range
Contact type Format
Word No. Bit No.
Discrete Outputs RWB-n N/A n: 0 ~ FFFF
Discrete Inputs RB-n N/A n: 0 ~ FFFF
¾
RWB- : can Read and Write.
Converting the address to decimal format and plus 1, it will immediately become the corresponding
“Standard Modbus” communication address.
¾
RB- (Discrete Inputs) : Read only.
Converting the address to decimal format and plus 10001, it will immediately become the corresponding
“Standard Modbus” communication address.
NOTE
1) Only first 10000 addresses can be converted to ”Standard Modbus” communication address.