Delta-electronics High-Speed PCI 12-Axis Motion Control Card PCI-DMC Instrukcja Użytkownika Strona 45

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 528
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 44
Chapter 3 Operating Principles | PCI-DMC-A01 / PCI-DMC-B01
Revised March, 2012 3-23
3) Enter the values of the arguments for motion control
Figure 3.35
StrVel item: Starting velocity. API function's argument variable “StrVel”.
MaxVel item: Maximum velocity. API function's argument variable “MaxVel”.
Acc. item: Time required to reach maximum velocity. API function's argument
variable “acc”.
Dec item: Time required to go from maximum velocity to 0. API function's argument
variable “dec”.
4) Select motion mode and set motion distance.
Figure 3.36
Abs. Checkbox: You must check this if you want motion displacement to use
absolute coordinates.
S-Curve checkbox: You must check this box if you wish to use the S-curve velocity
curve.
Dist. item: Motion distance. API function's argument variable “Distance”.
5) Set Servo Motor Power ON/OFF(servo on/servo off)
Figure 3.37
Click on the “SVON” button to execute the following procedure:
rt = _DMC_01_ipo_set_svon(gDMCCardNo, NodeID, SlotID , ON_OFF);
// ON_OFF: 0 – Servo Power OFF; 1 – Servo Power ON
Przeglądanie stron 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 527 528

Komentarze do niniejszej Instrukcji

Brak uwag