Delta-electronics High-Speed PCI 12-Axis Motion Control Card PCI-DMC Instrukcja Użytkownika Strona 438

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 528
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 437
Chapter 32 Parameter Monitoring API | PCI-DMC-A01 / PCI-DMC-B01
32-2 Revised March, 2012
32.1 _DMC_01_set_monitor
FORMAT
I16 PASCAL _DMC_01_set_monitor (U16 CardNo, U16 NodeID, U16 SlotID, U16 monitorw)
Purpose
Sets parameter to monitor.
Parameters
Name Data Type Unit Description
CardNo U16 Number Unit CardNo is between 0~15
NodeID U16 Number Unit Node ID
SlotID U16 Number Unit Slot ID
monitorw U16 Number Parameter to monitor
Example
U16 CardNo=0;
U16 NodeID=1;
U16 SlotID=0;
U16 monitorw=122; //Set DMCNET operation time
I16 status = _DMC_01_set_monitor (CardNo, NodeID, SlotID, monitorw);
Please see table 32.2 for monitor values
Przeglądanie stron 437
1 2 ... 433 434 435 436 437 438 439 440 441 442 443 ... 527 528

Komentarze do niniejszej Instrukcji

Brak uwag