Chapter 11 Velocity Motion Control Packet Protocol API | PCI-DMC-A01 / PCI-DMC-B01
Revised March, 2012 11-5
11.4 _DMC_01_set_velocity_torque_limit
FORMAT
I16 PASCAL _DMC_01_set_velocity_torque_limit (U16 CardNo, U16 NodeID, U16 SlotID,
U32 torque_limit)
Purpose
Sets the torque limit for velocity mode.
Parameters
Name Data Type Unit Description
CardNo U16 Number Unit CardNo is between 0~15
NodeID U16 Number Unit Node ID
SlotID U16 Number Unit Slot ID
torque_limit U32 Number Maximum torque
Example
U16 CardNo=0;
U16 NodeID =1;
U16 SlotID=0;
U32 torque_limit =50;
I16 status= _DMC_01_set_velocity_torque_limit (CardNo, NodeID, SlotID, torque_limit);