Delta Electronics Ethernet Extension Module DOP Instrukcja Użytkownika Strona 234

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 263
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 233
Chapter 13 Recipe Access Example
Revision March, 2014 13-17
Press icon. The following dialog box will pop-up and ask the users to enter the
password.
Please enter 12345678 in the filed of the password at the first time (12345678 is the
default setting value and the users can change it freely). After the correct password is
entered, the
icon will display on the tool bar at the left-bottom corner.
When eServer performs reading, due to enable auto refresh on startup, it will auto import
recipe to destination path, but if disable enable auto refresh on startup, please trigger the
character input element on HMI and enter TINA these four characters, then wait for 5
second to import recipe to destination path. Please refer to the figure below:
Przeglądanie stron 233
1 2 ... 229 230 231 232 233 234 235 236 237 238 239 ... 262 263

Komentarze do niniejszej Instrukcji

Brak uwag