ASDA-A User Manual Chapter 7 Parameters
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED 4th Edition 2005/11/30, HE03
7-49
P2 - 42 POV7
Moving Speed Setting of 7th Position Communication Addr.: 022AH
Default: 1000 Applicable Control Mode: P
Range: 1~5000
Unit: rpm
P2 - 43 POV8
Moving Speed Setting of 8th Position Communication Addr.: 022BH
Default: 1000 Applicable Control Mode: P
Range: 1~5000
Unit: rpm
P2 - 44 DOM
Digital Output Mode Setting Communication Addr.: 022CH
Default: 0 Applicable Control Mode: P
Range: 0~1
0: General output mode (DO is outputted according to the setting value of P2-18~P2-22)
1: Combination output mode
This output mode must be select and set when users want to use feed step control function.
Otherwise, the feed step control function can not be used normally.
P2 - 45 DOD
Combination Output Signal Delay Time Communication Addr.: 022DH
Default: 1 Applicable Control Mode: P
Range: 0~250
Unit: 4msec
Output signal holding delay time when positioning is completed.
P2 - 46 FSN
Feed Step Number Communication Addr.: 022EH
Default: 6 Applicable Control Mode: P
Range: 2~32
P2 - 47 PED
Position Deviation Clear Delay Time Communication Addr.: 022FH
Default: 0 Applicable Control Mode: P
Range: 0~250
Unit: 20msec
This function is disabled when its setting value is set to 0.
P2 - 48
BLAS Backlash Compensation of Feed Step Control Communication Addr.: 0230H
Default: 0 Applicable Control Mode: P
Range: 0~10312
Unit: pulse