The explanation of exception codes:
Exception
code
Explanation
01
Illegal function code:
The function code received in the command message is not available for the AC motor
drive.
02
Illegal data address:
The data address received in the command message is not available for the AC motor
drive.
03
Illegal data value:
The data value received in the command message is not available for the AC drive.
04
Slave device failure:
The AC motor drive is unable to perform the requested action.
10
Communication time-out:
If Pr.09-03 is not equal to 0.0, Pr.09-02=00~02, and there is no communication on the
bus during the Time-out detection period (set by Pr.09-03), “cE10” will be shown on the
keypad.