9 Application Instructions API 150-199
DVP-PLC Application Manual
9-74
Program Example 2:
When X1 = On, M1097 = On, indicating a right matrix rotation is performed. The 16-bit registers D0 ~ D2 will perform
a right matrix rotation and the result will be stored in the matrix of the 16-bit registers D20 ~ D22. The carry flag
M1095 will be “0”.
X1
MBRP D0 D20 K3
M1097
Before
Execution
After right
rotation
M1097=0
1
b0
0101010101
0
101
1010101010101010
101101010101010
b15
0
0
10101010101
0
101
1010101010101010
1011010101010100
0
0
M1095
M1095
MBR
Remarks:
Flag explanations:
Flags Function
M1095 Matrix rotation/displacement/output carry flag.
M1097 Matrix rotation/displacement direction flag.