6 Application Instructions API 00-49
DVP-PLC Application Manual
6-31
10
1
10
0
10
2
6 4 2
X17
X0
8
8
8
10
3
6
8
Y37 Y20
4-digit DIP switch in BCD format
4-digit BCD value
Using BIN instruction to store
the BIN value into D100
Using BCD instruction to convert the
content in D100 into a 4-digit BCD value.
4-digit 7-segment display in BCD format