Strona 2 - Preface

Chapter 1 Introduction|VFD-S Series Revision August 2006, SE08, SW V2.61 1-31.3 Installation Steps CASEHEAT SINKCOVERKNOB SCREWDIVISION PLATE Inst

Strona 3 - CAUTION!

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-45 d20 Counter Reset: Parameter value d20 programs Multi-Function Input Term

Strona 4

Chapter 5 Parameters|VFD-S Series 5-46 Revision August 2006, SE08, SW V2.61 d29 M0: 0: RUN 1: STOP, M1: no function, Direction is controlled by keyp

Strona 5

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-47 Group 5: Multi-step speeds and PLC (Process Logic Control) parameters 5-0

Strona 6 -

Chapter 5 Parameters|VFD-S Series 5-48 Revision August 2006, SE08, SW V2.61 Frequency60Hz50Hz40Hz30Hz20Hz15Hz10Hz0Hz5-095-105-115-125-135-145-15Pr.5-

Strona 7

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-49 Example 3 (Pr. 5-07 = d3) Execute one cycle step by step: The example sho

Strona 8 - Chapter 1 Introduction

Chapter 5 Parameters|VFD-S Series 5-50 Revision August 2006, SE08, SW V2.61 Example 5 (Pr. 5-07 = d1 Execute one cycle of the PLC program): In this e

Strona 9 - 0160T007S23A

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-51 1234567WeightsBit0=Forward1=ReverseDirection of 1st Pr.5-00 =FWD speed fo

Strona 10 - 1.3 Installation Steps

Chapter 5 Parameters|VFD-S Series 5-52 Revision August 2006, SE08, SW V2.61 Group 6: Protection Parameters 6-00 Over-Voltage Stall Prevention Unit

Strona 11 - 1.4 Storage

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-53 DC bus voltagetimeOver-voltagedetectionlevel Pr.6-01OutputFreq.timeOver-v

Strona 12

Chapter 5 Parameters|VFD-S Series 5-54 Revision August 2006, SE08, SW V2.61 6-03 Over-Torque Detection Mode (OL2) Factory Setting: d0 Settin

Strona 13

Chapter 1 Introduction|VFD-S Series 1-4 Revision August 2006, SE08, SW V2.61DIVISION PLATESCREW Reinstall Division Plate. Screw Torque: 5 to 6 kgf-c

Strona 14 - 2.2 Installation

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-55 1234560Hz or more50Hz10Hz5Hz020406080100120140160180 200Operationtime(min

Strona 15

Chapter 5 Parameters|VFD-S Series 5-56 Revision August 2006, SE08, SW V2.61 d20 Software protection enable (codE) d21 Reserved d22 CPU f

Strona 16 - 2.3 Dimensions

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-57 Group 7: Motor Parameters 7-00 Motor Rated Current Unit: 1 Settings

Strona 17

Chapter 5 Parameters|VFD-S Series 5-58 Revision August 2006, SE08, SW V2.61 Group 8: Special Parameters 8-00 DC Braking Current Level Unit: 1 Sett

Strona 18

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-59  DC Braking during Start-up is used for loads that may move before AC d

Strona 19

Chapter 5 Parameters|VFD-S Series 5-60 Revision August 2006, SE08, SW V2.61  Following a power failure, the AC drive will start its speed search op

Strona 20

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-61 8-15 Automatic Voltage Regulation (AVR) Factory Setting: d0 Sett

Strona 21 - Frame S1: VFD007S21B

Chapter 5 Parameters|VFD-S Series 5-62 Revision August 2006, SE08, SW V2.61 Group 9: Communication Parameters 9-00 Communication Address Setting

Strona 22

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-63 9-03 Time-out Detection Factory Setting: d0 Settings d0 Disable

Strona 23

Chapter 5 Parameters|VFD-S Series 5-64 Revision August 2006, SE08, SW V2.61 Terminal Unit). Users can select the desired mode along with the serial

Strona 24 - 5.0 [0.20]

Chapter 1 Introduction|VFD-S Series Revision August 2006, SE08, SW V2.61 1-53. If the AC motor drive is stored for more than 3 months, the tempera

Strona 25 - Frame S2: VFD007S11A

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-65 Start bit0123456StopbitStopbit8-bit character11-bit character frame( 8.N

Strona 26 - Frame S2: VFD007S11B

Chapter 5 Parameters|VFD-S Series 5-66 Revision August 2006, SE08, SW V2.61 3.2 ADR (Communication Address) Valid communication addresses are in the

Strona 27

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-67 RTU mode: Command message: Response message: ADR 01H ADR 01H CMD 03H

Strona 28

Chapter 5 Parameters|VFD-S Series 5-68 Revision August 2006, SE08, SW V2.61 ASCII Mode: Command message: Response message: STX ‘:’ STX ‘:’ ADR 1

Strona 29 - 2.4 Wiring

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-69 ASCII mode: LRC (Longitudinal Redundancy Check) is calculated by summing

Strona 30 - 2.4.1 Basic Wiring

Chapter 5 Parameters|VFD-S Series 5-70 Revision August 2006, SE08, SW V2.61 Step 5: Repeat step 3 and 4 until eight shifts have been performed. When

Strona 31 - For VFDXXXSXXA/B/D/U

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-71 Content Address Functions Bit 0-1 00: No function 01: Stop 10: Run 11

Strona 32 - NPN (sink mode)

Chapter 5 Parameters|VFD-S Series 5-72 Revision August 2006, SE08, SW V2.61 Content Address Functions 35: Reserved 36: PID error (Pld) 37: Reserve

Strona 33 - PNP (source mode)

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-73 Example of an exception response of command code 06H and exception code 0

Strona 34 - 2.4.2 External Wiring

Chapter 5 Parameters|VFD-S Series 5-74 Revision August 2006, SE08, SW V2.61 3.7 Communication program of PC: The following is a simple example of how

Strona 35

Chapter 1 Introduction|VFD-S Series 1-6 Revision August 2006, SE08, SW V2.61This page intentionally left blank.

Strona 36

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-75 Group A: PID Control A-00 Input Terminal for PID Feedback Factory S

Strona 37 - 2.4.4 Control Terminals

Chapter 5 Parameters|VFD-S Series 5-76 Revision August 2006, SE08, SW V2.61  When this parameter is set to gain =1, PID output is Derivative time.

Strona 38 - AFM circuit

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-77  This parameter selects the operation of the drive upon a loss of PID f

Strona 39 - ACI circuit

Chapter 5 Parameters|VFD-S Series 5-78 Revision August 2006, SE08, SW V2.61 the setting frequency of parameters, such as Max. operation frequency, 1s

Strona 40

Revision August 2006, SE08, SW V2.61 6-1 Chapter 6 Fault Code Information The AC motor drive has a comprehensive fault diagnostic system that inclu

Strona 41 - Power terminal

Chapter 6 Fault Code Information|VFD-S Series 6-2 Revision August 2006, SE08, SW V2.61 Fault Name Fault Descriptions Corrective Actions Overheating

Strona 42

Chapter 6 Fault Code Information|VFD-S Series Revision August 2006, SE08, SW V2.61 6-3 Fault Name Fault Descriptions Corrective Actions Over-curre

Strona 43

Chapter 6 Fault Code Information|VFD-S Series 6-4 Revision August 2006, SE08, SW V2.61 Fault Name Fault Descriptions Corrective Actions Communicati

Strona 44

Revision August 2006, SE08, SW V2.61 7-1 Chapter 7 Troubleshooting 7.1 Over Current (OC) ocAocdOC Over-current during accelerationOv

Strona 45

Chapter 7 Troubleshooting |VFD-S Series 7-2 Revision August 2006, SE08, SW V2.61 7.2 Ground Fault GFFGround faultNoYesIs output circuit(cable or m

Strona 46

Revision August 2006, SE08, SW V2.61 2-1 Chapter 2 Installation and Wiring 2.1 Ambient Conditions Install the AC motor drive in an environment with

Strona 47

Chapter 7 Troubleshooting |VFD-S Series Revision August 2006, SE08, SW V2.61 7-3 7.4 Low Voltage (Lv) Low voltageIs input power correct? Or power c

Strona 48 - Chapter 3 Start Up

Chapter 7 Troubleshooting |VFD-S Series 7-4 Revision August 2006, SE08, SW V2.61 7.5 Over Heat (OH) AC motor drive overheatsHeat sink overheatsChec

Strona 49 - 3.3 Trial Run

Chapter 7 Troubleshooting |VFD-S Series Revision August 2006, SE08, SW V2.61 7-5 7.7 Keypad Display is Abnormal Abnormal display or no displayCycle

Strona 50

Chapter 7 Troubleshooting |VFD-S Series 7-6 Revision August 2006, SE08, SW V2.61 7.9 Motor cannot Run Motor cannot run Check PU01 for normal

Strona 51

Chapter 7 Troubleshooting |VFD-S Series Revision August 2006, SE08, SW V2.61 7-7 7.10 Motor Speed cannot be Changed Motor can run butcannot c

Strona 52

Chapter 7 Troubleshooting |VFD-S Series 7-8 Revision August 2006, SE08, SW V2.61 7.11 Motor Stalls during Acceleration Motor stalls during accelerat

Strona 53

Chapter 7 Troubleshooting |VFD-S Series Revision August 2006, SE08, SW V2.61 7-9 7.13 Electromagnetic/Induction Noise Many sources of noise surround

Strona 54 - Setting parameters

Chapter 7 Troubleshooting |VFD-S Series 7-10 Revision August 2006, SE08, SW V2.61 4. Store within a relative humidity range of 0% to 90% and non-co

Strona 55

Revision August 2006, SE08, SW V2.61 8-1 Chapter 8 Maintenance and Inspections Modern AC motor drives are based on solid-state electronics technolo

Strona 56 - Chapter 5 Parameters

Chapter 8 Maintenance and Inspections|VFD-S Series 8-2 Revision August 2006, SE08, SW V2.61 Periodical Maintenance  Ambient environment Maintenance

Strona 57

Chapter 2 Installation and Wiring|VFD-S Series 2-2 Revision August 2006, SE08, SW V2.615. When installing multiple AC motor drives in the same cabi

Strona 58

Chapter 8 Maintenance and Inspections|VFD-S Series Revision August 2006, SE08, SW V2.61 8-3 Maintenance Period Check Items Methods and Criterion Dai

Strona 59

Chapter 8 Maintenance and Inspections|VFD-S Series 8-4 Revision August 2006, SE08, SW V2.61  DC capacity of main circuit Maintenance Period Check I

Strona 60

Chapter 8 Maintenance and Inspections|VFD-S Series Revision August 2006, SE08, SW V2.61 8-5  Printed circuit board and connector of main circuit Ma

Strona 61

Chapter 8 Maintenance and Inspections|VFD-S Series 8-6 Revision August 2006, SE08, SW V2.61 This page intentionally left blank

Strona 62

Revision August 2006, SE08, SW V2.61 Appendix A Specifications Voltage Class 115V Class 230V Class 460V Class Model Number VFD-XXXS 002 004

Strona 63

Appendix A Specifications|VFD-S Series A-2 Revision August 2006, SE08, SW V2.61 Installation Location Altitude 1,000 m or below, keep from corrosi

Strona 64

Revision August 2006, SE08, SW V2.61 Appendix B Accessories B.1 All Brake Resistors & Brake Units Used in AC Motor Drives Note: Please only use

Strona 65

Appendix B Accessories|VFD-S Series B-2 Revision August 2006, SE08, SW V2.61 installation and operation. B.1.1 Dimensions and Weights for Brake resi

Strona 66

Appendix B Accessories|VFD-S Series Revision August 2006, SE08, SW V2.61 B-3 B.2 EMI Filters The DELTA VFD-S Series 0.25-3HP, 115V, 230V, 460V AC dr

Strona 67

Appendix B Accessories|VFD-S Series B-4 Revision August 2006, SE08, SW V2.61 1. Use the cable with shielding (double shielding is the best). 2. T

Strona 68

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-32.3 Dimensions (Dimensions are in millimeter and [inch]) Frame

Strona 69

Appendix B Accessories|VFD-S Series Revision August 2006, SE08, SW V2.61 B-5 The length of motor cable When motor is driven by an AC motor drive of

Strona 70

Appendix B Accessories|VFD-S Series B-6 Revision August 2006, SE08, SW V2.61  If the length is too long, the stray capacitance between cables will

Strona 71

Appendix B Accessories|VFD-S Series Revision August 2006, SE08, SW V2.61 B-7 Order P/N: RF022S21BA 27(1.06)50(1.97)228(8.98)15(0.59)24(0.94)100(3.94

Strona 72

Appendix B Accessories|VFD-S Series B-8 Revision August 2006, SE08, SW V2.61 Order P/N: 12DKT1W3S POWER-IN Order P/N: 08TDT1W4S

Strona 73

Appendix B Accessories|VFD-S Series Revision August 2006, SE08, SW V2.61 B-9 Order P/N: 22DRT1W3S POWER-IN Order P/N: 35DRT1W3C POWER-IN

Strona 74 - Unit: 1

Appendix B Accessories|VFD-S Series B-10 Revision August 2006, SE08, SW V2.61 B.3 AC Reactor B.3.1 AC Input Reactor Recommended Value 230V, 50/60Hz,

Strona 75

Appendix B Accessories|VFD-S Series Revision August 2006, SE08, SW V2.61 B-11 460V, 50/60Hz, 3-Phase Inductance (mH) kW HP Fundamental Amps Max. co

Strona 76

Appendix B Accessories|VFD-S Series B-12 Revision August 2006, SE08, SW V2.61 may be damaged when over current occurs during operation.

Strona 77 - Unit: 0.1

Appendix B Accessories|VFD-S Series Revision August 2006, SE08, SW V2.61 B-13 Correct wiring M1M2MnreactorAC motor driveAC motor driveAC motor drive

Strona 78

Appendix B Accessories|VFD-S Series B-14 Revision August 2006, SE08, SW V2.61 Application 3 Question Used to improve the input power factor, to re

Strona 79

Chapter 2 Installation and Wiring|VFD-S Series 2-4 Revision August 2006, SE08, SW V2.61Frame S1: VFD002S11B, VFD002S21B 11.1[0.44]5.0 [0.20]74 .0 [

Strona 80

Appendix B Accessories|VFD-S Series Revision August 2006, SE08, SW V2.61 B-15 B.4 DC Choke Recommended Values 230V DC Choke Input voltage kW HP

Strona 81

Appendix B Accessories|VFD-S Series B-16 Revision August 2006, SE08, SW V2.61 B.5 Zero Phase Reactor (RF220X00A) Dimensions are in millimeter and (

Strona 82 - Current signal input(4-20mA)

Appendix B Accessories|VFD-S Series Revision August 2006, SE08, SW V2.61 B-17 B.6 Din Rail-DR01 (Dimensions are in millimeter) Models Screw SizeV

Strona 83

Appendix B Accessories|VFD-S Series B-18 Revision August 2006, SE08, SW V2.61 B.7 Remote Controller RC-01 (Dimensions are in millimeter) AFMGND +10

Strona 84

Appendix B Accessories|VFD-S Series Revision August 2006, SE08, SW V2.61 B-19 B.8 Conduit Bracket (BK-S) (Dimensions are in millimeter) 22.0(0.87)2

Strona 85

Appendix B Accessories|VFD-S Series B-20 Revision August 2006, SE08, SW V2.61 B.9 Non-fuse Circuit Breaker Chart Per UL 508C, paragraph 45.8.4, part

Strona 86 - Analog Frequency Meter

Revision August 2006, SE08, SW V2.61 Appendix C How to Select the Right AC Motor Drive The choice of the right AC motor drive for the application is

Strona 87

Appendix D CE|VFD-S Series C-2 Revision August 2006, SE08, SW V2.61 C.1 Capacity Formulas 1. When one AC motor drive operates one motor The starting

Strona 88

Error! Reference source not found. Error! Reference source not found.|VFD-S Series Revision August 2006, SE08, SW V2.61 C-3 2.3 When it is running

Strona 89

Appendix D CE|VFD-S Series C-4 Revision August 2006, SE08, SW V2.61 C.2 General Precautions Selection Note A. When the AC Motor Drive is connected

Strona 90

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-5Frame S1: VFD004S11A, VFD004S21A, VFD004S23A 5.0 [0.20]3.0[0.

Strona 91

Error! Reference source not found. Error! Reference source not found.|VFD-S Series Revision August 2006, SE08, SW V2.61 C-5 D. If the stall preve

Strona 92 - Potentiometer Scale

Appendix D CE|VFD-S Series C-6 Revision August 2006, SE08, SW V2.61 E. If 100% continuous torque is required at low speed, it may be necessary to u

Strona 93 - key to switch

Error! Reference source not found. Error! Reference source not found.|VFD-S Series Revision August 2006, SE08, SW V2.61 C-7 D. Gear reduction mot

Strona 94

Appendix D CE|VFD-S Series C-8 Revision August 2006, SE08, SW V2.61 AC motor drive Motor 18015514010080553803206012060 secondsBase freq.: 60HzV/F

Strona 95

Revision August 2006, SE08, SW V2.61 Appendix D CE DELTA ELECTRONICS, INC. EC Declaration of Conformity According to the Low Voltage Directive 73/2

Strona 96

Appendix D CE|VFD-S Series D-2 Revision August 2006, SE08, SW V2.61 DELTA ELECTRONICS, INC. EC Declaration of Conformity According to the Low Volt

Strona 98

Chapter 2 Installation and Wiring|VFD-S Series 2-6 Revision August 2006, SE08, SW V2.61Frame S1: VFD004S11B, VFD004S21B 3.0[0.12]5.0 [0.20]102.0 [4

Strona 99

Preface Thank you for choosing DELTA’s high-performance VFD-S Series. The VFD-S Series is manufactured with high-quality components and materials and

Strona 100 - Reset counter

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-7Frame S1: VFD007S21A, VFD007S23A 85.0 [3 .3 5]132.2[5.21]74.0

Strona 101 - RUN/STOP

Chapter 2 Installation and Wiring|VFD-S Series 2-8 Revision August 2006, SE08, SW V2.61Frame S1: VFD007S21B 11.1[0.44]3.0[0.12]5.0 [0.20]2.8 [0.11]

Strona 102

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-9Frame S1: VFD004S43A, VFD004S43E, VFD007S43A, VFD007S43E 11.1

Strona 103

Chapter 2 Installation and Wiring|VFD-S Series 2-10 Revision August 2006, SE08, SW V2.61Frame S1: VFD004S43B, VFD007S43B 5.0 [0.20]11.1[0.44]67 .8

Strona 104

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-11Frame S1: VFD002S21E, VFD004S21E, VFD007S21E, VFD015S23D 74.

Strona 105

Chapter 2 Installation and Wiring|VFD-S Series 2-12 Revision August 2006, SE08, SW V2.61Frame S2: VFD007S11A 86 .5 [3 .4 1]100.0 [3.94]129.0 [5.08]

Strona 106

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-13Frame S2: VFD007S11B 86.5 [3 .4 1]100.0 [3.94]73.0 [2 .8 8]9

Strona 107

Chapter 2 Installation and Wiring|VFD-S Series 2-14 Revision August 2006, SE08, SW V2.61Frame S2: VFD015S21D, VFD015S21E, VFD015S43D, VFD015S43E, VF

Strona 108

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-15Frame S2: VFD015S21U, VFD015S43U, VFD022S21U, VFD022S43U 86.

Strona 109

Chapter 2 Installation and Wiring|VFD-S Series 2-16 Revision August 2006, SE08, SW V2.612.4 Wiring After removing the front cover, check if the powe

Strona 110

WARNING! 1. DO NOT use Hi-pot test for internal components. The semi-conductor used in the AC motor drive is easily damaged by high-pressure. 2. Th

Strona 111

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-172.4.1 Basic Wiring  Make sure that power is only applied to

Strona 112

Chapter 2 Installation and Wiring|VFD-S Series 2-18 Revision August 2006, SE08, SW V2.61For VFDXXXSXXA/B/D/U 4.7k47KGrounding resistanceless than 1

Strona 113 - Output Frequency

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-19For VFDXXXSXXE NPN (sink mode) B2U/T1V/T2W/T3IM3~NOTE: Do no

Strona 114

Chapter 2 Installation and Wiring|VFD-S Series 2-20 Revision August 2006, SE08, SW V2.61For VFDXXXSXXE PNP (source mode) B2U/T1V/T2W/T3IM3~NOTE: Do

Strona 115

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-212.4.2 External Wiring MotorOutput AC Line ReactorPower Supply

Strona 116

Chapter 2 Installation and Wiring|VFD-S Series 2-22 Revision August 2006, SE08, SW V2.612.4.3 Main Terminals Connections Terminal Symbol Explanatio

Strona 117 - Computer

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-23 DO NOT connect phase-compensation capacitors or surge absor

Strona 118

Chapter 2 Installation and Wiring|VFD-S Series 2-24 Revision August 2006, SE08, SW V2.612.4.4 Control Terminals Control Terminal Wiring (Factory Set

Strona 119 - ( 7.E.1)

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-25Terminal Symbol Terminal Function Factory Settings (NPN mode)

Strona 120

Chapter 2 Installation and Wiring|VFD-S Series 2-26 Revision August 2006, SE08, SW V2.61Terminal Symbol Terminal Function Factory Settings (NPN mode

Strona 121

Table of Contents Preface ...i Table of C

Strona 122

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-27Digital outputs (MO1, MCM)  Make sure to connect the digital

Strona 123

Chapter 2 Installation and Wiring|VFD-S Series 2-28 Revision August 2006, SE08, SW V2.612.4.5 Main Circuit Terminals VFD002S11A/11B, VFD004S11A/11B

Strona 124

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-29VFD002S21B/23A, VFD004S21B/23A/43A/43B/43E, VFD007S21B/23A/43

Strona 125

Chapter 2 Installation and Wiring|VFD-S Series 2-30 Revision August 2006, SE08, SW V2.61VFD002S21A/E, VFD004S21A/E, VFD007S21A/E DC ReactorBrakingR

Strona 126

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-31VFD007S11A/B AC Input Line TerminalPower terminal MotorC

Strona 127

Chapter 2 Installation and Wiring|VFD-S Series 2-32 Revision August 2006, SE08, SW V2.61VFD015S21U/43D/43E/43U, VFD022S21U/23D/43D/43E/43U AC Input

Strona 128

Chapter 2 Installation and Wiring|VFD-S Series Revision August 2006, SE08, SW V2.61 2-33VFD015S21D/E, VFD022S21D/E BrakingResistorDC ReactorGroundPow

Strona 129

Chapter 2 Installation and Wiring|VFD-S Series 2-34 Revision August 2006, SE08, SW V2.61 This page intentionally left blank

Strona 130

Revision August 2006, SE08, SW V2.61 3-1 Chapter 3 Start Up 3.1 Preparations before Start-up Carefully check the following items before proceeding.

Strona 131

Chapter 3 Start Up| VFD-S Series 3-2 Revision August 2006, SE08, SW V2.613.2 Operation Method Refer to 4.2 How to operate the digital keypad and cha

Strona 132 - Sleep Function

Chapter 3 Start Up...3-1 3.1 Preparations before Start-up...

Strona 133 - Per output

Chapter 3 Start Up| VFD-S Series Revision August 2006, SE08, SW V2.61 3-3NOTE 1. Stop running immediately if any fault occurs and refer to the troub

Strona 134 - Fault Code Information

Chapter 3 Start Up| VFD-S Series 3-4 Revision August 2006, SE08, SW V2.61This page intentionally left blank

Strona 135

Revision August 2006, SE08, SW V2.61 4-1 Chapter 4 Digital Keypad Operation 4.1 Description of the Digital Keypad RUNFWDREVSTOPMIN. MAX.RUNSTOP/RESE

Strona 136

Chapter 4 Digital Keypad Operation|VFD-S Series 4-2 Revision August 2006, SE08, SW V2.61Display Message Descriptions The internal PLC process step

Strona 137 - 6.2 Reset

Chapter 4 Digital Keypad Operation|VFD-S Series Revision August 2006, SE08, SW V2.61 4-3 4.4 How to Operate the Digital Keypad STARTTo shift dataSet

Strona 138 - Chapter 7 Troubleshooting

Chapter 4 Digital Keypad Operation|VFD-S Series 4-4 Revision August 2006, SE08, SW V2.61This page intentionally left blank

Strona 139 - 7.3 Over Voltage (OV)

Revision August 2006, SE08, SW V2.61 5-1 Chapter 5 Parameters The VFD-S parameters are divided into 11 groups by property for easy setting. In most

Strona 140 - 7.4 Low Voltage (Lv)

Chapter 5 Parameters|VFD-S Series 5-2 Revision August 2006, SE08, SW V2.61 5.1 Summary of Parameter Settings : The parameter can be set during opera

Strona 141 - 7.6 Overload

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-3 Pr. Explanation Settings Factory SettingNOTE 460V series: d4.0V to d51

Strona 142 - 7.8 Phase Loss (PHL)

Chapter 5 Parameters|VFD-S Series 5-4 Revision August 2006, SE08, SW V2.61 Pr. Explanation Settings Factory SettingNOTE2-00 Source of Master Frequen

Strona 143 - 7.9 Motor cannot Run

7.9 Motor cannot Run ... 7-6 7.10 Motor Speed canno

Strona 144

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-5 Pr. Explanation Settings Factory SettingNOTE3-00 Analog Output Signal d0

Strona 145

Chapter 5 Parameters|VFD-S Series 5-6 Revision August 2006, SE08, SW V2.61 Pr. Explanation Settings Factory SettingNOTE4-05 Multi-Function Input Ter

Strona 146 - 7.14 Environmental Condition

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-7 Pr. Explanation Settings Factory SettingNOTE5-02 3rd Step Speed Freq. d

Strona 147

Chapter 5 Parameters|VFD-S Series 5-8 Revision August 2006, SE08, SW V2.61 Pr. Explanation Settings Factory SettingNOTE6-05 Over-Torque Detection T

Strona 148

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-9 Group 7 Motor Parameters Pr. Explanation Settings Factory SettingNOTE7-

Strona 149

Chapter 5 Parameters|VFD-S Series 5-10 Revision August 2006, SE08, SW V2.61 Pr. Explanation Settings Factory SettingNOTE9-00 Communication Address

Strona 150

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-11 Pr. Explanation Settings Factory SettingNOTEA-07 PID Output Freq. Limit

Strona 151

Chapter 5 Parameters|VFD-S Series 5-12 Revision August 2006, SE08, SW V2.61 5.2 Parameter Settings for Applications  Speed Search Applications Purp

Strona 152

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-13  Two-wire/three-wire Applications Purpose Functions Related Parameters

Strona 153

Chapter 5 Parameters|VFD-S Series 5-14 Revision August 2006, SE08, SW V2.61  Over-torque Setting Applications Purpose Functions Related Parameters

Strona 154 - Appendix A Specifications

Appendix C How to Select the Right AC Motor Drive...C-1 C.1 Capacity Formulas ...

Strona 155

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-15  Output Signal during Running Applications Purpose Functions Related P

Strona 156 - Appendix B Accessories

Chapter 5 Parameters|VFD-S Series 5-16 Revision August 2006, SE08, SW V2.61  Output Signal when Frequency Attained Applications Purpose Functions

Strona 157

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-17 5.3 Description of Parameter Settings Group 0: User Parameters

Strona 158 - B.2 EMI Filters

Chapter 5 Parameters|VFD-S Series 5-18 Revision August 2006, SE08, SW V2.61 d4 Display forward/reverse command (Frd/rEv) 0-04 Content of Mul

Strona 159

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-19 0-07 Password Input Unit: 1 Settings d0 to d999 Factory Setting: d0

Strona 160

Chapter 5 Parameters|VFD-S Series 5-20 Revision August 2006, SE08, SW V2.61 3 chances to enter the correctpassword.1st time displays "d 1"

Strona 161 - B.2.1 Dimensions

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-21 bit 5 bit4 Bit 3 bit 1 Setting for Pr. 0-09 0 0 0 1 2 0 8 (factory

Strona 162 - Order P/N: RF022S21BA

Chapter 5 Parameters|VFD-S Series 5-22 Revision August 2006, SE08, SW V2.61 Group 1: Basic Parameters 1-00 Maximum Output Frequency (Fmax) Unit: 0.1

Strona 163 - POWER-IN

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-23  This parameter sets the Mid-Point Voltage of any V/f curve. With this

Strona 164

Chapter 5 Parameters|VFD-S Series 5-24 Revision August 2006, SE08, SW V2.61  If the Upper Limit of Output Frequency is 50Hz and the Maximum Output

Strona 165 - B.3 AC Reactor

Revision August 2006, SE08, SW V2.61 1-1 Chapter 1 Introduction 1.1 Receiving and Inspection This VFD-S AC motor drive has gone through rigorous qua

Strona 166 - 1/2 2 3 20 32

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-25  The JOG function can be selected using Multi-function Input terminals

Strona 167

Chapter 5 Parameters|VFD-S Series 5-26 Revision August 2006, SE08, SW V2.61 1-16 Acceleration S-Curve 1-17 Deceleration S-Curve Settings d0 t

Strona 168

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-27 Group 2: Operation Method Parameters 2-00 Source of Master Frequency Com

Strona 169

Chapter 5 Parameters|VFD-S Series 5-28 Revision August 2006, SE08, SW V2.61 2-01 Source of Operation Command Factory Setting: d0 Settings d

Strona 170

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-29 RUNSTOPRUNSTOPFrequencyFrequencyTimeTimeoutputfrequencyoutputfrequencymot

Strona 171 - Zero Phase Reactor

Chapter 5 Parameters|VFD-S Series 5-30 Revision August 2006, SE08, SW V2.61 2-05 Loss of ACI Signal (4-20mA) Factory Setting: d0 Settings d

Strona 172 - B.6 Din Rail-DR01

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-31 Group 3: Output Function Parameters 3-00 Analog Output Signal (AFM)

Strona 173 - B.7 Remote Controller RC-01

Chapter 5 Parameters|VFD-S Series 5-32 Revision August 2006, SE08, SW V2.61 3-02 Desired Frequency Attained Unit: 0.1 Settings d1.0 to d400 Hz

Strona 174 - B.8 Conduit Bracket (BK-S)

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-33 Preliminary Counter Value Attained Output(Pr. 3-04=d3)(Pr. 3-05 to Pr. 3-

Strona 175 - Fuse Specification Chart

Chapter 5 Parameters|VFD-S Series 5-34 Revision August 2006, SE08, SW V2.61 Setting Function Description d10 PLC Program Running the output will

Strona 176

Chapter 1 Introduction|VFD-S Series 1-2 Revision August 2006, SE08, SW V2.611.1.3 Series Number Explanation 0160T007S23AProduction numberProduction

Strona 177 - C.1 Capacity Formulas

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-35 Group 4: Input Function Parameters 4-00  Potentiometer Bias Frequency

Strona 178 - )(_____103

Chapter 5 Parameters|VFD-S Series 5-36 Revision August 2006, SE08, SW V2.61 Example 3: The example also shows the popular method. The whole scale o

Strona 179 - C.2 General Precautions

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-37 Example 6: In this example, a negative bias is used to provide a noise

Strona 180 - Load duty-cycle

Chapter 5 Parameters|VFD-S Series 5-38 Revision August 2006, SE08, SW V2.61 Hz 0V4mA10V20mA30060Potentiometer ScaleMax.OutputFreq.60HzPr.1-000Hz 0V4

Strona 181 - Appendix D CE

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-39 Explanations: d0 Parameter Disable: Enter value (d0) to disable any Multi

Strona 182 - Motor torque

Chapter 5 Parameters|VFD-S Series 5-40 Revision August 2006, SE08, SW V2.61 NOTE When value d3 is selected for Pr. 4-04, this will over ride any valu

Strona 183 - AC motor drive Motor

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-41 GNDD7 Multi-step 1D8 Multi-step 2D9 Multi-step 3Mx "Close": Ope

Strona 184 - Appendix D CE

Chapter 5 Parameters|VFD-S Series 5-42 Revision August 2006, SE08, SW V2.61 FrequencyMaster FrequencyAccelerationinhibitAcceleration inhibitActual op

Strona 185 - EC Declaration of Conformity

Chapter 5 Parameters|VFD-S Series Revision August 2006, SE08, SW V2.61 5-43 GNDB.B.(N.O.)setting by d13B.B.(N.C.)setting by d14Mx "Close":

Strona 186

Chapter 5 Parameters|VFD-S Series 5-44 Revision August 2006, SE08, SW V2.61 GNDsetting by d17setting by d18Mx "Close": Run PLC.Mx "Clo