LCP-1250A4FDRx
11 09/20/2011
Rev. S0
9) Byte 128 to 255 had been set hex 00.
Digital Diagnostic Monitoring Interface
Alarm and Warning Thresholds (2-Wire Address A2h)
Address
#
Bytes
Name Value (Dec.) Unit Note
00-01 2 Temp High Alarm T
(MAX.)+8
℃
1
02-03 2 Temp Low Alarm T
(MIN.)-8
06-07 2 Temp Low Warning T
(MIN.)-3
08-09 2 Voltage High Alarm 3.8 Volt
12-13 2 Voltage High Warning 3.5
14-15 2 Voltage Low Warning 3.1
mA 2
18-19 2 Bias Low Alarm I
-5
20-21 2 Bias High Warning I
+7
24-25 2 TX Power High Alarm -2 dBm
26-27 2 TX Power Low Alarm -11.5
30-31 2 TX Power Low Warning -10.5
32-33 2 RX Power High Alarm -1 dBm
36-37 2 RX Power High Warning -2
38-39 2 RX Power Low Warning -18
56-91 36 External Calibration Constants
92-94 3 Reversed
96-97 2 Real Time Temperature
98-99 2 Real Time Supply Voltage
Real Time Tx Bias Current
102-103
2 Real Time Tx Optical Power
104-105
2 Real Time Rx Received Power
110 1 Optional Status/ Control Bits 4
111 1 Reserved
Optional Set of Alarm and Warning
Notes:
1) T
C
: Case Operating temperature
2) I
OP
: Operating current at room temperature. The min. setting current is 0 mA.
3) Byte 95 contains the low order 8bits of sum of bytes 0-94