DeviceNet Remote I/O Communication Module RTU-DNET
DVP-PLC Application Manual
33
Common services
Implemented for
Service code
Class Instance
Service name
0x05 No Yes Reset
0x0E Yes Yes Get_Attribute_Single
0x10 No No Find_Next_Object_Instance
Class 0x02 – Message router object
Class attribute
Attribute ID Access rule Name Data type
1 Get Revision UINT
6 Get MaxIdClass UINT
7 Get MaxIdInstance UINT
Instance
Attribute ID Access rule Name Data type
2 Get NumAvailable UINT
3 Get NumActive UINT
Common services
Implemented for
Service code
Class Instance
Service name
0x0E Yes Yes Get_Attribute_Single
Class 0x03 – DeviceNet object
Class attribute
Attribute ID Access rule Name Data type
1 Get Revision UINT
Instance attribute
Attribute ID Access rule Name Data type
1 Get MACID USINT
2 Get BaudRate USINT
3 Get/Set BusofInterrupt BOOL
4 Get/Set BusofCounter USINT
5 Get
AllocationInfo
AllocationChoice
MasterNodeAddress
BYTE
USINT
6 Get MACIDSwitchChanged BOOL
7 Get BaudRateSwitchChanged BOOL
8 Get MACIDSwitchValue USINT
9 Get BaudRateSwitchValue USINT