Series Valve Temperature Controller
Instruction Sheet
Thanks you very much for choosing Delta DTV series valve temperature controller. Please read this instruction sheet before using your DTV to ensure proper
operation. Keep this instruction handy for quick reference.
Warning
DANGER! CAUTION! ELECTRIC SHOCK! When the power is on, DO NOT touch the AC terminals in case an electric shock may occur. Make sure
the power is disconnected when you check the input power.
DTV is an OPEN-TYPE device. If it will cause serious injury to workers or damage on other equipments when used in a dangerous environment,
please make sure it is installed in an automatic safety protection device.
1. Always use recommended solder-less terminals: Fork terminal with isolation (M3 screw, Max. width 7.2mm). Please be sure to tighten them properly and
make sure the wire is connected to the correct terminal.
2. Prevent dust or metallic debris from falling into the device and cause malfunction. DO NOT modify or uninstall DTV series without being permitted. DO
NOT use empty terminals.
3. Keep away from high-voltage and high-frequency environment during installation in case of interference. Prevent using DTV in premises which contain:
(a) dust or corrosive gas; (b) high humidity and high radiation; (c) shock and vibration
4. The power has to be switched off when wiring or changing temperature sensor.
5. Make sure to use compensation wire which matches the thermocouple when extending or connecting the thermocouple wire.
6. Use wires with resistance when extending or connecting the platinum resistance sensor.
7. Keep the wire as short as possible when wiring a sensor to the temperature controller. Separate the power cable and load wire in order to prevent
interference and induced noise.
8. DTV is an open-type device. Make sure to install it in an enclosure which prevents dust and humidity in case of an electric shock.
9. Make sure the power cables and signal device are installed correctly before switching on the power; otherwise serious damage may occur.
10. DO NOT touch the terminals or repair the device when the power is on; otherwise an electric shock may occur.
11. Please wait for one minute after the power is switched off to allow the capacitor to discharge. DO NOT touch the internal wiring within this period.
12. DO use dry cloth and DONOT use acid or alkaline liquid to clean the device.
Display, LED & Pushbuttons
PV: Present value
SV: Set value
%: Output percentage
AT: Auto-tuning indicator
A/M: Manual control indicator
OUT1/OUT2: Output indicator
ALM1/ALM2: Alarm output indicator
Manual/auto mode switch key
Selection/setup key
Switching page key
Left-shifting the digit
Ordering information
DTV
1
2
3
4
5
Series name DTV: Delta V series valve temperature controller
1 2 3 4
Panel size
(W × H)
4896: 1/8 DIN W48 × H96 mm
9696: 1/4 DIN W96 × H96 mm
5
R: Valve, relay output SPST (250VAC, 5A)
Specifications
Power input AC100 ~ 240V, 50/60Hz
Input power range 85% ~ 110%, rated voltage
Power consumption Less than 5VA
Display
2-line, 7-segment LED, 4bits and 2 bits of valve openness display
PV in red, SV and valve openness in green.
Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK
Platinum resistance: Pt100, JPt100
Input temperature sensor
Analog input: 0 ~ 5V, 0 ~ 10V, 0 ~ 20mA, 4 ~ 20mA, 0 ~ 50mA
Control method PID, PID programmable control, manual, On/Off
Control output type Relay output: SPST, Max. load 250V, 5A resistive load
Display scale 1 digit after the decimal point, or no decimal point
Sampling cycle Analog input: 0.15 sec; thermocouple/platinum resistance: 0.4 sec
Vibration resistance 10 ~ 55Hz 10m/s
2
3 axes 10 min.
Shock resistance Max. 300m/s
2
3 axes 6 directions, 3 times each
Ambient temperature 0°C ~ +50°C
Storage temperature -20°C ~ +65°C
Operation altitude Less than 2,000m
Ambient humidity 35% ~ 80% RH (non-condensing)
1